Sažetak
Arterial stenosis alters blood pressure and flow distributions throughout the arterial network, potentially producing measurable hemodynamic differences between healthy and affected limbs. This study investigates the effects of femoral artery stenosis using a one-dimensional model of a 129-segment arterial tree solved by the transmission line method (TLM). Arterial wall viscoelasticity is represented by the Kelvin–Voigt model, while nonlinear pressure losses associated with stenosis are approximated using an effective vessel diameter within the linear TLM formulation. Resting-state simulations are performed for a healthy reference case and three degrees of femoral artery stenosis (30%, 50%, and 70%), maintaining identical prescribed pulsatile inlet flow conditions. The resulting brachial and tibial pressures, ankle–brachial index (ABI), and blood velocities in the healthy and stenosed limbs are compared. The results demonstrate that increasing stenosis severity causes a substantial reduction in distal tibial pressure and ABI, whereas brachial pressure remains only weakly affected. Furthermore, stenosis induces a pronounced left–right asymmetry in femoral artery blood velocity. These findings demonstrate the capability of one-dimensional arterial network models to characterize the hemodynamic consequences of femoral artery stenosis. The limitations of the present approach include the absence of distal vasodilatation and the use of a prescribed inlet flow rate, motivating future investigations with pressure-controlled inlet conditions.
Ključne riječi
one-dimensional blood flow femoral artery stenosis transmission line method arterial tree ankle–brachial index hemodynamics