Sažetak
This work gives an assessment of the application of two ultrafiltration membrane types, which are the same in pore size but different in chemistry and configuration module, for textile wastewater treatment. Characterization was based on the solute rejection data of two commercial membranes, flat sheet polyethersulfone (PES) and tubular multi-channel ceramic membrane, and flux decline was provided using polyethylene glycol (PEG) solutions of different molar mass. The permeate flux recovery after chemical cleaning was evaluated, and the efficiency of wastewater treatment was estimated on the basis of the analysis of textile wastewater and permeate. The permeate flux decline study showed that fouling was less likely to occur when PES membrane was used for waste-water treatment. PES flat membrane has proven to be more effective in the treatment of wastewater with total organic carbon (TOC) and colour removal efficiency of 72 % and 85 % respectively.
Ključne riječi
textile wastewater membrane processes ceramic membrane polymer membrane membrane characterization