First results from on-going CIGRÉ enquiry on reliability of high voltage equipment

dr. sc. Krešimir Meštrović, prof. v. š.

Sažetak

CIGRÉ WG A3.06 in cooperation with WG B3.02 is presently carrying out a worldwide survey of failures in service on high voltage equipment rated for voltages greater than or equal to 60 kV. The survey covers circuit breakers (only SF6 technology), disconnectors, earthing switches, instrument transformers and GIS. The collection of information from utilities about their equipment populations, and about failures that occur in these populations, started in January 2004, and will go on until December 2007. At present (April 2005) 36 utilities from 18 countries have submitted information about their apparatus populations, together with a total of 1446 failure cards, each describing one failure. Many more utilities are currently collecting information for the survey, and a large number of extra cards will be submitted. The information will, when the data acquisition has been completed, be subjected to extensive statistical analyses with the purpose of obtaining trustworthy information on reliability and failures for the considered component types.

Ključne riječi

High voltage apparatus - Failure statistics - Reliability survey - Service experience